Technical Data

  »powerShrink 200« »powerShrink 300« »powerShrink 400« »powerShrink 600«
Shrinkable tool length 400 mm 600 mm 600 mm 600 mm
Maximum inner diameter of induction coil »varOct« ― 45,8 mm 45,8 mm 45,8 mm
Maximum inner diameter of the induction coil with shielding discs 50 mm 50 mm 50 mm 50 mm
Shrink-clampable diameter with 14 kVA induction coil 3–32 mm 3–32 mm 3–32 mm 3–32 mm
Shrink-clampable diameter with 22 kVA induction coil ― ― ― 16–50 mm
Requirements        
Pneumatic requirement 6–8 bar ― ― 6–8 bar
Electrical load 400 V 3~ /N/PE, 50 Hz 400 V 3~ /N/PE, 50 Hz 400 V 3~ /N/PE, 50 Hz 400 V 3~ /N/PE, 50 Hz
Main cable supply 3 m 3 m 3 m 3 m
Connected load induction heat shrink system 14 kVA 15 kVA 15 kVA 15 kVA 15 kVA
Connected load induction heat shrink system 22 kVA ― ― ― 23 kVA
Weights        
No cooling system, air cooling beneath the induction coil ~ 35 kg ― ― ―
Workbench version, »zStream« ― ― ~ 150 kg ―
Workbench version, cooling bells,
Additional weight of water cooler
― ~ 143 kg
~ 42 kg
~ 153 kg
~ 42 kg
―
With table, »zStream« ― ― ~ 240 kg ―
With table, cooling bells ― ~ 274 kg ~ 284 kg ~ 410 kg

»powerShrink 400 | 11«

Induction coil axis Zmax 1,100 mm
Induction coil axis Zmax 460 mm
Plug for alternating operation of the 2 induction coil axes
Additional cooling bell D 40–50 mm (optional)
Adjustable tool support
Mounting pot for mounting rings with a 100 mm length reducer adapter